IBM Support

PK93924: DXL ATTRIBUTE GENERATES AN ERROR ' CANNOT MODIFY ATTRIBUTE ON A DELETED OBJECT' IF THE VIEW HAS DELETED Objects SHOWN.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • TLOG#52710
    
    Description
    ===========
    
    A DXL Attribute in a module will generate an error 'Cannot
    Modify Deleted Objects' if the current view has deleted objects
    and they are set to be shown 'View ? Show ? Deletions'
    

Local fix

  • As a workaround you can modify the DXL behind the attribute, (
    Edit >
    Attributes ) and then put the entire DXL script for the DXL
    attribute
    within the following loop.
    
    if(!isDeleted obj) {
    
    
    }
    
    This will have the DXL run only for non-deleted Objects.
    

Problem summary

  • A DXL Attribute in a module will generate an error 'Cannot
    
    Modify Deleted Objects' if the current view has deleted objects
    and they are set to be shown 'View > Show > Deletions'
    

Problem conclusion

  • When you convert layout DXL to attribute DXL with a deleted
    object in the view, there are no longer DXL errors.
    

Temporary fix

  • As a workaround you can modify the DXL behind the attribute, (
    
    Edit >
    Attributes ) and then put the entire DXL script for the DXL
    attribute
    within the following loop.
    
    if(!isDeleted obj) {
    
    
    }
    
    This will have the DXL run only for non-deleted Objects.
    

Comments

APAR Information

  • APAR number

    PK93924

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    920

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2009-08-14

  • Closed date

    2009-12-04

  • Last modified date

    2009-12-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R920 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSKR2T","label":"IBM Engineering Requirements Management DOORS"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"9.2","Edition":"","Line of Business":{"code":"LOB59","label":"Sustainability Software"}}]

Document Information

Modified date:
01 May 2020