Error description
IBM Rational Developer for System z - RDz - v9.5.1 IBM Developer for z Systems - IDz v14.0.6 an v14.1.2 RDz 9.5.1 Zunit fails with error 'CRRZT0041E' when generating test case for a COBOL member which contains non-unique declarations. Sample: WORKING-STORAGE SECTION. 01 Double-Def-A. 05 Double-Def-B OCCURS 5. 10 DD-1 PIC 9(4). 10 DD-2 PIC X. 10 DD-3 PIC X. 10 DD-4 PIC X. 10 DD-2 PIC X. 10 DD-6 PIC X. The following error message is shown: "An error occurred while opening the test case Entry Editor Reason CRRZT0041E The model could not be read from com.ibm.etools.zunit.exception.ZUnitException: CRRZT0041E The model could not be read from L/zUnitTempProject/source/TEST.cbl, exception [java.lang.RuntimeException: CRRT0044E Non-unique "DD-2" found while importing.]."
Local fix
Problem summary
Zunit fails with error 'CRRZT0041E' when generating test case for a COBOL member which contains non-unique declarations.
Problem conclusion
This error comes from COBOL importer since it does not allow non-unique declarations. zUnit has been corrected so that the file contains parameter declarations only could be consumed by the importer. The problem listed in this APAR has been resolved with IBM Rational Developer for z Systems V9.5.1.9 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI98659
Reported component name
DEV FOR Z SYS
Reported component ID
5724T0700
Reported release
951
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-06-01
Closed date
2018-10-23
Last modified date
2018-10-23
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z SYS
Fixed component ID
5724T0700
Applicable component levels
R951 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"951","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
18 October 2021