IBM Support

PI98659: IBM DEVELOPER FOR Z SYSTEMS: RDZ 9.5.1 ZUNIT FAILS WITH ERROR CRRZT0041E WHEN GENERATING TEST CASE

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • IBM Rational Developer for System z - RDz - v9.5.1
    IBM Developer for z Systems - IDz v14.0.6 an v14.1.2
    
    RDz 9.5.1 Zunit fails with error 'CRRZT0041E' when generating
    test case for a COBOL member which contains non-unique
    declarations.
    
    Sample:
    
    WORKING-STORAGE SECTION.
          01 Double-Def-A.
             05 Double-Def-B OCCURS 5.
              10 DD-1 PIC 9(4).
              10 DD-2 PIC X.
              10 DD-3 PIC X.
              10 DD-4 PIC X.
              10 DD-2 PIC X.
              10 DD-6 PIC X.
    
    The following error message is shown:
    "An error occurred while opening the test case Entry Editor
    
    Reason
    CRRZT0041E The model could not be read from
    
    com.ibm.etools.zunit.exception.ZUnitException: CRRZT0041E The
    model could not be read from L/zUnitTempProject/source/TEST.cbl,
    exception
    [java.lang.RuntimeException: CRRT0044E Non-unique "DD-2" found
    while importing.]."
    

Local fix

Problem summary

  • Zunit fails with error 'CRRZT0041E' when generating
    test case for a COBOL member which contains non-unique
    declarations.
    

Problem conclusion

  • This error comes from COBOL importer since it does not allow
    non-unique declarations.
    zUnit has been corrected so that the file contains parameter
    declarations only could be consumed by the importer.
    
    The problem listed in this APAR has been resolved with
    IBM Rational Developer for z Systems V9.5.1.9 Fix Pack which
    is available from the Recommended Fixes support download page:
    http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI98659

  • Reported component name

    DEV FOR Z SYS

  • Reported component ID

    5724T0700

  • Reported release

    951

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-06-01

  • Closed date

    2018-10-23

  • Last modified date

    2018-10-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DEV FOR Z SYS

  • Fixed component ID

    5724T0700

Applicable component levels

  • R951 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"951","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
18 October 2021