APAR status
Closed as unreproducible.
Error description
A report is authored with a master-detail relationship between a list and a page set query. Both the master and detail queries contain an identical filter based on a multi-select parameter. If a singleton is added to the report page based on a separate query which returns an unrelated data item and does not use that filter, the report returns incorrect values. The detail list is only filtered on one of the parameter values instead of all the user's selections. If the singleton is removed, then the detail query is filtered on all of the selections.
Local fix
Add the data item used in the singleton to the master query and display it directly on the page without using a singleton data container.
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos Analytic 11.0.13.0 * ****************************************************************
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PI97873
Reported component name
COG REPORT STUD
Reported component ID
5724W12RS
Reported release
B0A
Status
CLOSED UR5
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-05-11
Closed date
2018-11-02
Last modified date
2018-11-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
RB0A PSN
UP
[{"Business Unit":{"code":"BU048","label":"IBM Software"},"Product":{"code":"SSCHNWW","label":"Report Authoring v11x"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"B0A","Edition":"","Line of Business":{"code":"","label":""}}]
Document Information
Modified date:
02 November 2018