APAR status
Closed as fixed if next.
Error description
A report is authored that runs in the classic viewer, and a report view is created from that report. When the report view is run in IE, the HTTP request to run the report contains a Referer header of the form http://server:port/bi/. When the same report view is run in Chrome the Referer header for that request is several thousand characters long. This can cause different error messages depending on the web server used if the web server has set limits on the maximum size for an HTTP header.
Local fix
Increase the size limit for request headers on your web server, or run the report view in Internet Explorer.
Problem summary
**************************************************************** * USERS AFFECTED: * * All Users * **************************************************************** * PROBLEM DESCRIPTION: * * See Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to IBM Cognos Analytic 11.0.12.0 * ****************************************************************
Problem conclusion
Temporary fix
Comments
APAR Information
APAR number
PI96299
Reported component name
COG REPORT STUD
Reported component ID
5724W12RS
Reported release
B0A
Status
CLOSED FIN
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2018-04-05
Closed date
2018-06-29
Last modified date
2018-06-29
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Applicable component levels
RB0A PSN
UP