IBM Support

PI95706: DUPLICATED DEPENDENCIES ID WILL CREATED ON THE COMMUNICATION DIAGRAM.

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • - Reproduce
    If do below procedure for communication diagram, duplicate
    dependencies ID will be created.
    
    
    1. Create the Class A and Class B.
    
    2. Create communication diagram.
    
    3. Place Class A and Class B in created communication diagram.
    
    4. Create a dependency to be Class A --> Class B.
    
    : After confirming the feature, it is named ": Class B".
    
    5. Create the same above dependency again.
    
    : After confirming the feature, it is named ": Class B_9999".
    
    6. Create the same above dependency again.
    
    : After confirming the feature, it is named ": Class B_9999".
    
    7. It seems that No.5 and No.6 are the same physical ID at the
    point of
    the procedure No.6 above, and if one feature is changed, the
    other feature is also changed.
    
    Also tested with version 8.3, still created <Class name>_9999.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Rhapsody                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * DUPLICATED DEPENDENCIES ID WILL CREATED ON THE COMMUNICATION *
    * DIAGRAM.                                                     *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed by fixing the name of the dependency.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI95706

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    820

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2018-03-25

  • Closed date

    2018-06-17

  • Last modified date

    2018-06-17

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R820 PSY

       UP



Document information

More support for: Rational Rhapsody

Software version: 820

Reference #: PI95706

Modified date: 17 June 2018