Fixes are available
APAR status
Closed as program error.
Error description
RunTests JUnit output does not produce files for each test suite within a parent suite. STEPS TO REPRODUCE: 1. Create a RIT project with a test suite that runs two other suites. 2. Ensure that the project database connection is correct. 3. Run the parent suite using RunTests with the -jUnitDir parameter. For example: runtests -environment myEnv -project myproject.ghp -run Suite.gts -junitDir c:\temp\JunitResults This worked correctly on RIT version 8.6. EXPECTED RESULTS: Three JUnit XML files, one for each suite such as: TEST-Suite_2017-12-06_02-11-19-011.xml TEST-Suite1_2017-12-06_02-11-18-011.xml TEST-Suite2_2017-12-06_02-11-19-011.xml ACTUAL RESULTS: One JUnit file named for the last suite to be run such as: TEST-Suite2_2017-12-06_02-12-40-012.xml WORKAROUND: Add the parameter -jUnitLegacy to the command line. For example: runtests -environment myEnv -project myproject.ghp -run Suite.gts -junitDir c:\temp\JunitResults -junitLegacy
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of JUnit and Rational Integration Tester. * **************************************************************** * PROBLEM DESCRIPTION: * * JUnit style reporting was incorrectly using an output file * * name of the last child suite run rather than the name of the * * parent suite. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in release 9.2.0.1
Temporary fix
Comments
APAR Information
APAR number
PI91342
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-12-11
Closed date
2018-07-17
Last modified date
2018-07-17
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 October 2021