Fixes are available
APAR status
Closed as program error.
Error description
The Stub Usage feature uses a KairosDB instance to store data. By default, an H2 database is used and the internal KairosDB statistics are saved every 60 seconds. This causes the RTCP workspace to grow in size. The file that grows is <RTCP workspace>/kairosdb/h2db/kairosdb.h2.db WORKAROUND: 1. Stop RTCP Delete kairosdb.h2.db to remove all history. It will be re-created automatically 2. Edit the kairosdb.properties file. On Windows typically at: C:\Program Files\IBM\RationalTestControlPanel\usr\servers\RTCPServer\apps\k airosdb.war\WEB-INF\kairosdb\conf Non-Windows typically: /opt/IBM/RationalTestControlPanel/usr/servers/RTCPServer/apps/ka irosdb.war/WEB-INF/kairosdb/conf 3. Change the cron parameter to reduce the frequency: kairosdb.reporter.schedule=0 0 0 * * ? (save only once per week) 4. Re-start RTCP
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of Rational Integration Tester using virtual service * * metrics * **************************************************************** * PROBLEM DESCRIPTION: * * Internal logging of information could result in excessive * * storage usage within the metrics database. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Fixed in 9.2.1.1
Temporary fix
Comments
APAR Information
APAR number
PI90897
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
901
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-11-30
Closed date
2018-12-21
Last modified date
2018-12-21
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSN
UP
R911 PSN
UP
R920 PSN
UP
R921 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
19 October 2021