IBM Support

PI87765: IBM DEVELOPER FOR Z SYSTEMS (RDZ/IDZ): "ADATA,EX(ELAXHASM)" OPTION GENERATED WITH THE 'REBUILD PROJECT OR SUBPROJECT'

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • IBM Rational Developer for System z - RDz - v9.5.1.5
    IBM Developer for z Systems - IDz - v14
    
    When we ask a 'Rebuild project or subproject', RDz/IDz always
    wrongly generates the "ADATA,EX(ELAXHASM)" option.
    
    Re-creation steps:
    
    1 - create an ASM project,
    2 - add a subproject
    3 - add 2 programs, say CICSASM.asm and ECDASM.asm
    4 - define 2 property groups: CICSP_ASM and ECD_CICS_ASM
    5 - for CICSP_ASM property group, call ELAXFAST procedure which
    includes 2 steps: CICSP (CICS preprocessor) and ASM. Support
    Error Feedback never selected.
    6 - assign CICSP_ASM property group to CICSASM.asm
    7 - for ECD_CICS_ASM property group, call ELAXAECD procedure
    which includes 2 steps: AECD (precompiler) and CICSP (CICS
    preprocessor). Support Error Feedback never selected.
    8 - assign ECD_CICS_ASM property group to ECDASM.asm
    9 - right click on CICSASM.asm, select 'Generate JCL'>
    'Compile Link'  ==> generated JCL does not contain support error
    feedback parameter which is fine.
    10 - right click on ECDASM.asm, select 'Generate JCL'>
    'Compile Link' ==> generated JCL does not contain support error
    feedback parameter which is fine as well.
    11 - Right click on the subproject and select 'Rebuild
    subproject'
    ==> each procedure contains the support error feedback parameter
    
    "PARM.ECD=('ADATA','EX(ADX(ELAXHASM))')" which is not supported
    by all steps (abend).
    

Local fix

Problem summary

  • RDz/IDz always wrongly generates the "ADATA,EX(ELAXHASM)"
    option, regardless of the "Support error feedback" setting in
    the property group.
    

Problem conclusion

  • The property group checkbox "Support error feedback" will honor
    generating "ADATA,EX(ELAXHASM)", instead of automatically adding
     that option. Furthermore, a new subproject property (under the
    Build tab) has been added to override the property group
    selection, if checked, which it is by default.
    
    The problem listed in this APAR has been resolved with
    IBM Rational Developer for z Systems V9.5.1.7 Fix Pack which
    is available from the Recommended Fixes support download page:
    http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI87765

  • Reported component name

    ID/Z HOST

  • Reported component ID

    5724T0723

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-09-22

  • Closed date

    2018-01-29

  • Last modified date

    2018-01-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    DEV FOR Z SYS

  • Fixed component ID

    5724T0700

Applicable component levels

  • R951 PSY

       UP



Document information

More support for: Rational Developer for System z

Software version: 950

Reference #: PI87765

Modified date: 29 January 2018