IBM Support

PI86218: DWA:RECEIVE ERROR CRCRW5074E WHEN EXPAND MODULE VIEWS IF ACCESS RIGHTS SET TO SPECIFIC and inc attributes "remote"

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Issue reproducible in DWA 9.6.1.9
    Issue NOT reproducible on DWA 9.3 and 9.6.1.4
    DWA: receive error CRCRW5074E when expand module views when
    access right of module and views are not inherit from parent and
    module includes attributes "remote Created by", "Remote Created
    on, "Remote Last modified on and by" which the DWA user does not
    have A access
    
    Steps to reproduce:
    1- set up access right on module and views as follows:
    Module access specific
    User A RMCDA
    Everyone Else RMCD
    View A (default for module) access specific
    User B RMCD
    Everyone Else R
    Ensure module inc attributes "remote Created by", "Remote
    Created on, "Remote Last modified on and by" and Everyone Else
    do not have A access
    2- log in DWA as a user that is not defined in step1 (has
    Everyone Else access)
    3- In DWA, expand the views of the module
    Receive " CRCRW5074E an unrecognised error has occurred"
    
    Workaround: baseline the module and the error no longer occurs.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users/environments affected.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Receive error CRCRW5074E when expand module views when       *
    * access right of module and views are not inherit from        *
    * parent.                                                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    DWA Interop fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.6.1.10 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI86218

  • Reported component name

    TLOGIC DOORS WE

  • Reported component ID

    5724V97WA

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-08-22

  • Closed date

    2017-12-14

  • Last modified date

    2017-12-14

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS WE

  • Fixed component ID

    5724V97WA

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI86218

Modified date: 14 December 2017