Error description
If a physical webMethods or Email transport is edited to create an invalid configuration, this transport cannot be corrected and used until RIT is re-started. When running a test or stub you see the following error message: the transport is unavailable: The transport has been deleted. STEPS TO REPRODUCE: 1. Create a webMethods or Email transport 2. Configure and run a test or stub that uses this transport 3. Edit the physical transport to change its connection details so that the test/stub fails 4. Run the test or stub 5. Correct the change to the transport 6. Run the test or stub EXPECTED RESULTS: The test or stub executes correctly ACTUAL RESULTS: The test or stub fails with the message "The transport has been deleted."
Local fix
WORKAROUND: Re-start RIT
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of the Email and webMethods transports * **************************************************************** * PROBLEM DESCRIPTION: * * If the physical transport is configured so that it cannot * * connect, the transport cannot be used even if the * * configuration is corrected. * * Tests fail with "transport deleted" errors. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
Update to RIT version 9.1.1
Temporary fix
Comments
APAR Information
APAR number
PI83469
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-06-22
Closed date
2017-10-03
Last modified date
2017-11-03
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSN
UP
R901 PSN
UP
R910 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
18 October 2021