APAR status
Closed as program error.
Error description
In IBM Developer for z Systems V14.0.0.4, the Remote CICS Application launch uses port 8001 when no port is specified in the Advanced Connection Options for generating the DTCN profiles. Until the issue is fixed, the user can manually update the port number through the DTCN transaction panel
Local fix
- Logon on the CICS region terminal - Invoke the DTCN transaction - Update the port number according to the Debugger daemon port number of the client
Problem summary
**************************************************************** * USERS AFFECTED: * * Users who use Remote CICS Application debug configurations * * with a daemon port other than 8001. * **************************************************************** * PROBLEM DESCRIPTION: * * When the debug daemon is configured to use a port other than * * 8001, the Remote CICS Application debug configuration * * ignores the setting. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The Remote CICS Application debug configuration was fixed so that it automatically detects the port that the debug daemon is using so that the remote profile (DTCN) is correctly updated.
Temporary fix
Comments
APAR Information
APAR number
PI82269
Reported component name
DEV FOR Z SYS
Reported component ID
5724T0700
Reported release
E00
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-05-29
Closed date
2017-06-30
Last modified date
2017-06-30
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
DEV FOR Z SYS
Fixed component ID
5724T0700
Applicable component levels
RE00 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSJK49","label":"IBM Developer for z Systems"},"Component":"","ARM Category":[],"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"E00","Edition":"","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
30 June 2017