Fixes are available
Rational ClearCase Fix Pack 15 (8.0.1.15) for 8.0.1
Rational ClearCase Fix Pack 5 (9.0.0.5) for 9.0
Rational ClearCase Fix Pack 1 (9.0.1.1) for 9.0.1
Rational ClearCase Fix Pack 6 (9.0.0.6) for 9.0
Rational ClearCase Fix Pack 2 (9.0.1.2) for 9.0.1
Rational ClearCase Fix Pack 16 (8.0.1.16) for 8.0.1
Rational ClearCase Fix Pack 17 (8.0.1.17) for 8.0.1
Rational ClearCase Fix Pack 3 (9.0.1.3) for 9.0.1
Rational ClearCase Fix Pack 4 (9.0.1.4) for 9.0.1
Rational ClearCase Fix Pack 18 (8.0.1.18) for 8.0.1
Rational ClearCase Fix Pack 5 (9.0.1.5) for 9.0.1
Rational ClearCase Fix Pack 19 (8.0.1.19) for 8.0.1
Rational ClearCase Fix Pack 6 (9.0.1.6) for 9.0.1
Rational ClearCase Fix Pack 20 (8.0.1.20) for 8.0.1
Rational ClearCase Fix Pack 7 (9.0.1.7) for 9.0.1
Rational ClearCase Fix Pack 21 (8.0.1.21) for 8.0.1
Rational ClearCase Fix Pack 8 (9.0.1.8) for 9.0.1
Rational ClearCase Fix Pack 22 (8.0.1.22) for 8.0.1
Rational ClearCase Fix Pack 9 (9.0.1.9) for 9.0.1
Rational ClearCase Fix Pack 23 (8.0.1.23) for 8.0.1
Rational ClearCase Fix Pack 10 (9.0.1.10) for 9.0.1
Rational ClearCase Fix Pack 24 (8.0.1.24) for 8.0.1
Rational ClearCase Fix Pack 11 (9.0.1.11) for 9.0.1
Rational ClearCase Fix Pack 25 (8.0.1.25) for 8.0.1
Rational ClearCase Fix Pack 12 (9.0.1.12) for 9.0.1
Rational ClearCase Fix Pack 13 (9.0.1.13) for 9.0.1
APAR status
Closed as program error.
Error description
After you install Rational ClearCase 9.0.0.4 on SLES 12.2, you may see the following errors in the syslog: systemd[16300]: Failed to get udev device from devnum 253:0: No such device systemd[1]: Failed to get udev device from devnum 253:0: No such device systemd[16300]: Failed to get udev device from devnum 253:0: No such device systemd[1]: Failed to get udev device from devnum 253:0: No such device
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * Users of ClearCase dynamic views on SuSE 12 SP2 * **************************************************************** * PROBLEM DESCRIPTION: * * On SuSE 12 SP2 systems with ClearCase installed, you may * * observe repetitive messages such as this in the syslog: * * * * systemd[16300]: Failed to get udev device from devnum 253:0: * * No such device * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The ClearCase MVFS has been updated to provide the information which systemd is querying in this situation, to eliminate the log messages, in ClearCase versions 8.0.1.15, 9.0.0.5, and 9.0.1.1.
Temporary fix
Comments
APAR Information
APAR number
PI78498
Reported component name
CLRCASE MSITE W
Reported component ID
5724G3200
Reported release
900
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2017-03-20
Closed date
2017-09-13
Last modified date
2017-09-13
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
CLRCASE MSITE W
Fixed component ID
5724G3200
Applicable component levels
R801 PSY
UP
R900 PSY
UP
R901 PSY
UP
Document Information
Modified date:
12 January 2022