  • STEPS TO REPRODUCE:
    
    1. Create a stub with has no guard condition but multiple guards
    2. The stub is configured to append a repeating value to a tag
    3. Send an event with the repeating elements to the stub
    
    EXPECTED RESULTS
    
    The repeating elements are tagged correctly
    
    
    ACTUAL RESULTS
    
    If the stub event is the first in the list, the repeated tagging
    works correctly.
    The tag contains:
    
    {One, Two, Three, Four}
    
    If the stub event follows another that has a guard condition,
    the tagging results in:
    
    {, One, Two, Three, Four}
    
    There is an additional empty value at the start of the tag
    
    WORKAROUND:
    None
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of stub guard conditions and multi-value tags.         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Tagging of repeating data structures was adding an extra     *
    * empty value when the event followed a Guard condition.       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Update to version 9.1.1 of the product and tagging of repeating
    values works correctly.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI78343

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    901

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-03-16

  • Closed date

    2017-10-11

  • Last modified date

    2017-10-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSN

       UP

  • R871 PSN

       UP

  • R900 PSN

       UP

  • R901 PSN

       UP

  • R910 PSN

       UP

  • R911 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"901","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
19 October 2021