IBM Support

PI76242: OLEACTIVATE AND OLEDELETE FUNCTIONS DOES NOT WORK WHEN COLUMN CONTAINING OLE IS NOT VISIBLE

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • If a column containing OLE object is not visible, oleActivate
    and oleDelete functions do not work as expected.
    Following variants are affected:
    
    string oleActivate(Object o, Column c, integer index)
    oleActivate fails and returns message "OLE index specified is
    not valid"
    
    bool oleActivate(Object o)
    oleActivate returns true, but OLE object is not activated
    
    string oleDelete(Object o, Column c, integer index)
    oleDelete fails and returns message "OLE Index too large"
    
    Also, when OLE is activated (even manually), and then scroll
    right/left in the module such that the column containing OLE is
    no longer visible, the activated OLE is closed automatically.
    

Local fix

  • NA
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All DOORS users.                                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The oleActivate and oleDelete functions do not work when the *
    * column containing OLE is not visible.                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.7 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI76242

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-08

  • Closed date

    2019-07-11

  • Last modified date

    2019-07-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI76242

Modified date: 11 July 2019