IBM Support

PI76082: APPLYING FILTER ON SPECIFIC LAYOUT DXL COLUMN PRODUCES A DIAGNOSTIC LOG

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • If you try to filter on a column, where that column contains
    layout code which opens and closes a baseline, a diagnostic log
    and DXL errors will be produced.
    
    To recreate:
    
     - create a module containing some objects and baseline it
     - add a layout column with the following code:
    
    "
    Module m = current
    Baseline b = getMostRecentBaseline (m)
    Module mBase = load(m, b, false)
    display "xyz"
    
    if(isLastObjectInDXLSet(obj)){
    	close(mBase)
    }
    "
    
     - give the column a title and save the it as part of a view
     - select Tools;Filter;Define
     - in the Columns tab of the resulting dialog, select the layout
    column, enter some text to filter on and click <Apply>
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users/environments affected.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Applying a filter on a column, where that column contains    *
    * layout code which opens and closes a baseline, a diagnostic  *
    * log and DXL errors will be produced.                         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.6.1.9 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI76082

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2017-02-06

  • Closed date

    2017-12-20

  • Last modified date

    2017-12-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI76082

Modified date: 20 December 2017