PI73528: INABILITY TO CREATE OSLC LINKS WITH CHANGE INTEGRATION ENABLED WITHOUT CHANGE MANAGEMENT

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • It is not possible to create OSLC links when the Change
    Management integration is used without Change Management.
    
    The Change Management integration can be enabled without
    actually enabling Change Management, enabling only Requirements
    Implementation. With this configuration it should be possible
    create OSLC links.
    
    To recreate:
    
     - in a module enable the Change Management integration with
    "Enable Requirements Implementation" active and with "Enable
    Requirements Change Management" not active
     - right-click an object, select Link, and observe the OSLC link
    sub menus (e.g. Implemented By). It is not possible to select
    them
    
    Workaround:
    
    Modify line 445 of lib\dxl\config\formal.dxl as follows:
    
    Replace "if (!null m && cmintIsCsintON(m) &&
    !cmHasUMCFlagFile(m))"
    With "if (!null m && cmintIsCsintON(m) && cmRcmIsEnabled(m))
    
    Notably this also removes the ability to attempt to create OSLC
    links in Unmanaged Changes mode.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users/environments affected.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * It is not possible to create OSLC links when the Change      *
    * Management integration is used without Change Management.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • This has been resolved in the DOORS 9.6.1.9 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI73528

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-12-09

  • Closed date

    2017-12-19

  • Last modified date

    2017-12-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI73528

Modified date: 19 December 2017