IBM Support

PI68980: WHEN A PROJECT IS CLONED OR A TEST RUN ON RTCP, THE TRUST AND KEY STORE INFORMATION IS REMOVED FOR JMS BROKER CONFIGURATION

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • STEPS TO REPRODUCE:
    
    1. Create a test that uses a JMS Broker Transport
    
    2. Configure the JMS Broker to use a Trust and or a Key Store
    using system environment variables in it's path
    
    3. Run the test on RTCP or Clone the project
    
    4.  The test will fail because the Trust and Key store are
    removed
    
    5.  Running the test from the cloned project will fail because
    the Trust and Key store removed
    
    
    EXPECTED RESULTS:
    
    The test should work fine
    
    
    ACTUAL RESULTS:
    
    The test fails because the Trust and or the Key store values
    needed for authentication are missing
    
    WORKAROUND:
    
    Specify the path of the Trust and Key store using absolute file
    path, e.g. C:\temp\....
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester that clone or       *
    * publish projects to Rational Test Control Panel that contain *
    * identity store resources.                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When cloning or publishing a project, identity store         *
    * resources that use system tags would fail to find the        *
    * corresponding key store resources when subsequently used.    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in version 9.0.1.1
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI68980

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-09-09

  • Closed date

    2016-12-12

  • Last modified date

    2016-12-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSN

       UP

  • R871 PSN

       UP

  • R900 PSN

       UP

  • R901 PSY

       UP



Document information

More support for: Rational Test Workbench

Software version: 900

Reference #: PI68980

Modified date: 12 December 2016