PI67066: RATIONAL DEVELOPER FOR SYSTEM Z (RDZ) : IN THE COBOL EDITOR, MENU MANAGER '$SAVEFILEBEFORE$FULLNAME' COMMAND SAVES "AFTER"

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rational Developer for System z - RDz - v9.5.0
    
    Description :
    Via Menu Manager, when trying to issue the following command :
      ex 'XXX.XXXXX.EXEC(REXX)'  '$savefilebefore$fullname'
    the save is done after execution of the REXX instead of before.
    This is observed with large Cobol sources.
    The behavior is however correct with an LPEX editor.
    
    Steps to reproduce :
    - Create a Menu Manager item for COBOL files (*.cbl and *.cob)
    without override info or data set filter plus show on generic
    and show output.
    - Select the context "MVS Files in COBOL Editor"
    - Open a COBOL source, change it, then execute the procedure
    from right-mouse click context.
    ==> Output shows unchanged source
    

Local fix

Problem summary

  • The basic text editor save action was not doing an immediate
    upload of the file contents.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI67066

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-08-05

  • Closed date

    2016-10-27

  • Last modified date

    2016-10-27

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R951 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
16 October 2021