A fix is available
APAR status
Closed as program error.
Error description
Rational Developer for z Systems - When attempting to create a new filter from the Remote Systems view, the 'Next' button is greyed out although the filter string is valid. For example: Right click on MVS Files>>New Filter Filter string value,ABDC.* The 'Next' button may be greyed out when it should not be The workspace .log file may have an entry like the following: org.eclipse.rse.ui Error Fri August 10:49:02 CEST 2016 Error in createPageControls of SystemNewFilterWizard java.lang.NullPointerException at org.eclipse.rse.ui.filters.dialogs.SystemNewFilterWizard.getFilt erNameValidator(Unknown Source) at org.eclipse.rse.ui.filters.dialogs.SystemNewFilterWizard.getFilt erNameValidator(Unknown Source) at org.eclipse.rse.ui.filters.dialogs.SystemNewFilterWizard.createP ageControls(Unknown Source) at org.eclipse.jface.wizard.WizardDialog.createPageControls(Unknown Source) at org.eclipse.jface.wizard.WizardDialog.createContents(Unknown Source) at org.eclipse.jface.window.Window.create(Unknown Source) at org.eclipse.jface.dialogs.Dialog.create(Unknown Source) at org.eclipse.jface.window.Window.open(Unknown Source) at org.eclipse.rse.ui.actions.SystemBaseDialogAction.run(Unknown Source) at org.eclipse.jface.action.Action.runWithEvent(Unknown Source) at org.eclipse.jface.action.ActionContributionItem.handleWidgetSele ction(Unknown Source) at org.eclipse.jface.action.ActionContributionItem.access$2(Unknown Source) at org.eclipse.jface.action.ActionContributionItem$5.handleEvent(Un known Source) at org.eclipse.swt.widgets.EventTable.sendEvent(Unknown Source) at org.eclipse.swt.widgets.Display.sendEvent(Unknown Source) at org.eclipse.swt.widgets.Widget.sendEvent(Unknown Source) at org.eclipse.swt.widgets.Display.runDeferredEvents(Unknown Source) at org.eclipse.swt.widgets.Display.readAndDispatch(Unknown Source) at org.eclipse.e4.ui.internal.workbench.swt.PartRenderingEngine$9.r un(Unknown Source) at org.eclipse.core.databinding.observable.Realm.runWithDefault(Unk nown Source) at org.eclipse.e4.ui.internal.workbench.swt.PartRenderingEngine.run (Unknown Source) at org.eclipse.e4.ui.internal.workbench.E4Workbench.createAndRunUI( Unknown Source) at org.eclipse.ui.internal.Workbench$5.run(Unknown Source) at org.eclipse.core.databinding.observable.Realm.runWithDefault(Unk nown Source) at org.eclipse.ui.internal.Workbench.createAndRunWorkbench(Unknown Source) at org.eclipse.ui.PlatformUI.createAndRunWorkbench(Unknown Source) at org.eclipse.ui.internal.ide.application.IDEApplication.start(Unk nown Source) at org.eclipse.equinox.internal.app.EclipseAppHandle.run(Unknown Source) at org.eclipse.core.runtime.internal.adaptor.EclipseAppLauncher.run Application(Unknown Source) at org.eclipse.core.runtime.internal.adaptor.EclipseAppLauncher.sta rt(Unknown Source) at org.eclipse.core.runtime.adaptor.EclipseStarter.run(Unknown Source) at org.eclipse.core.runtime.adaptor.EclipseStarter.run(Unknown Source) at sun.reflect.NativeMethodAccessorImpl.invoke0(Native Method) at sun.reflect.NativeMethodAccessorImpl.invoke(Unknown Source) at sun.reflect.DelegatingMethodAccessorImpl.invoke(Unknown Source) at java.lang.reflect.Method.invoke(Unknown Source) at org.eclipse.equinox.launcher.Main.invokeFramework(Unknown Source) at org.eclipse.equinox.launcher.Main.basicRun(Unknown Source) at org.eclipse.equinox.launcher.Main.run(Unknown Source) at org.eclipse.equinox.launcher.Main.main(Unknown Source)
Local fix
The error seen is only associated to the workspace, so starting a new workspace resolves the issue.
Problem summary
See error description.
Problem conclusion
The problem listed in this APAR has been resolved with IBM Rational Developer for System z V9.5.1.1 iFix which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI67014
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
950
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2016-08-05
Closed date
2016-09-08
Last modified date
2016-09-08
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R951 PSY
UP
[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"950","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]
Document Information
Modified date:
17 October 2021