IBM Support

PI62951: 'LABEL/NAME' BUTTON IS DISAPPEARED FROM FEATURE DIALOGUE OF DATAFLOW IN SEQUENCE DIAGRAM

A fix is available

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • In feature dialogue of elements, a 'Name' button should appear
    at the right of label name input box when Label mode is ON. And
    a 'Label' button should appears at the right of name  input box
    when Label mode is OFF.
    
    But for Rhapsody 815 SysML model, 'Label' or 'Name' button is
    disappeared from feature dialogue of dataflow in sequence
    diagram.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Rhapsody users                                               *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In feature dialogue of dataflow in sequence diagram., a      *
    * 'Name' button should appear at the right of label name input *
    * box when Label mode is ON. And a 'Label' button should       *
    * appears at the right of name  input box                      *
    * when Label mode is OFF.                                      *
    * But in model with AUTOSAR/SysML profile  instead of text box *
    * and  'Name'/'Label" button  you get a combo box of the port  *
    * attributes as its options                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • Fixed in Rhapsody 8.2 -
    The property General::Message::AllowRegularPortsInDataFlow that
    cause AUTOSAR/SysML behavior was moved from the AUTOSAR project
    stereotype to the ARPackage stereotype so you will get the combo
    box only in  sequence diagram inside ARPackage
    This property is now supported in message level so it can be
    customize, and you can get the desired behavior for each
    dataflow
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI62951

  • Reported component name

    TLOGIC RHAPSODY

  • Reported component ID

    5724V74RP

  • Reported release

    815

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-05-23

  • Closed date

    2016-12-05

  • Last modified date

    2016-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC RHAPSODY

  • Fixed component ID

    5724V74RP

Applicable component levels

  • R815 PSN

       UP



Document information

More support for: Rational Rhapsody

Software version: 815

Reference #: PI62951