PI58364: RDZ IN PLI EDITOR CICS COMMAND CALCULATION IS INVALIDLY ANNOTATED AS ERROR

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rational Developer for System z 9.1.1.2 in PLI Editor CICS
    command calculation is invalidly annotated as error
    
    EXEC CICS statement with some arithmetic's inside is annotated
    by PL/I and LPEX Editor .
    
    EXEC CICS WRITEQ TS QUEUE (TSQ_NAME)
                   FROM (BER_PROT)
                 LENGTH (LEN + 36);  <--- LEN + 36 is annotated
    

Local fix

Problem summary

  • The RDz CICS parser does not allow arithmetic expressions in the
     CICS data value fields.F
    

Problem conclusion

  • Modified RDz CICS parser to allow arithmetic expressions in CICS
     data value fields.
    
    The problem listed in this APAR has been resolved with
    IBM Rational Developer for System z V9.1.1.4 Fix Pack which
    is available from the Recommended Fixes support download page:
    http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI58364

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2016-03-02

  • Closed date

    2016-09-30

  • Last modified date

    2016-09-30

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R911 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"910","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date:
15 October 2021