IBM Support

PI52384: COPY PASTE AN OBJECT WITH A DISCOVERED OSLC LINK IN IT & THE COPIED OVER LINK WILL APPEAR ONLY UNTIL THE MODULE IS REOPENED

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • 1) Select a DOORS object (DOORS Object A) which has a link to a
    Rhapsody Design Manager (RDM) object and create a copy (DOORS
    object B) within the same DOORS Module (e.g. using Copy&Paste)
    
    DOORS object B will have the same link to RDM object. The link
    can be followed successfully.
    
    2) Change DOORS edit mode (switch to Read-Only and back to
    Exclusive Edit).
    
    DOORS Object B still has the link to RDM object. The link can
    still be followed successfully.
    
    3) Close the DOORS Module and reopen.
    
    DOORS Object B will have lost its link to RDM object.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Copy paste an object with a discovered OSLC link in it and   *
    * the copied over link will appear only until the module is    *
    * reopened.                                                    *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This has been resolved in the DOORS 9616 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI52384

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-11-12

  • Closed date

    2016-03-29

  • Last modified date

    2016-03-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI52384