PI49162: USING LOAD(BASELINE) PERM IN BATCH MODE RESULTS IN DXL ERRORS

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Using load(Baseline) perm in batch mode results in DXL errors.
    The behavior is specific to the display parameter of the perm,
    which when set to true results in the DXL errors.
    
    Steps to reproduce:
    - Create a module and create an initial baseline
    - Run the following DXL:
    /**********************/
    string mName = "/Prj A/Mod 1"
    Module mm = read(mName,false)
    Module mb
    mb = load(mm,baseline(0,1,null), true)
    /**********************/
    
    The display parameter is usually used with the expectation of
    being able to access the default view info (when set).
    

Local fix

  • Use load perm with display set to false; access view related
    info via currentView perm
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Using load (baseline) perm in batch mode results in DXL      *
    * errors                                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This has been resolved in the DOORS 9616 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI49162

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    930

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-09-22

  • Closed date

    2016-03-29

  • Last modified date

    2016-03-29

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.3

Reference #: PI49162

Modified date: 29 March 2016