Error description

  • If the Software AG webMethods server is configured to use HTTP
    Proxy it can prevent messages being captured in Recording
    Studio.
    
    Clicking the Test Transport button on the physical webMethods
    Integration Server transport returns a good status.
    No messages are captured in Recording studio and no errors are
    logged.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester working with        *
    * Software AG Web Methods Integration Server (WMIS).           *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Previously, the Rational Integration Tester server side      *
    * components for Software AG Web Methods Integration Server    *
    * (WMIS) could not be configured to bypass a proxy server      *
    * other than through server network configuration. This        *
    * prevented any messages being received in Recording Studio.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 8.7.1 of Rational
    Integration Tester by changing the pipeline handler code to not
    use the proxy by default. To use the proxy, change the new
    "useProxy" setting in the package configuration file to "true".
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI44381

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    860

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-07-06

  • Closed date

    2015-10-07

  • Last modified date

    2015-10-07

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSN

       UP

  • R871 PSY

       UP



Document information

More support for: Rational Test Workbench

Software version: 8.6

Reference #: PI44381

Modified date: 07 October 2015