Fixes are available
APAR status
Closed as program error.
Error description
STEPS TO REPRODUCE: 1. Create a test with a Subscribe step. This can be done on both Linux and Windows This can be on any type of file the user has normal rights to. 2. Create a test with a Run Command step that will try to delete the file. This will run after the Subscribe step. 3. Run the test. EXPECTED RESULTS: The customer was expecting to be able to delete the file. ACTUAL RESULTS: The file on Windows is locked and can't be modified. The file on Linux will be deleted.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester working with * * subscribing to file * **************************************************************** * PROBLEM DESCRIPTION: * * STEPS TO REPRODUCE: * * * * 1. Create a test with a Subscribe step. This can be done on * * both * * Linux and Windows * * This can be on any type of file the user has normal * * rights * * to. * * * * 2. Create a test with a Run Command step that will try to * * delete * * the file. * * This will run after the Subscribe step. * * * * 3. Run the test. * * * * * * * * * * EXPECTED RESULTS: * * * * The customer was expecting to be able to delete the file. * * * * * * ACTUAL RESULTS: * * * * The file on Windows is locked and can't be modified. * * * * The file on Linux will be deleted. * * * * Error Description * **************************************************************** * RECOMMENDATION: * * Upgrade to Rational Integration Tester v9.0.0.1 which * * includes a fix for this issue * ****************************************************************
Problem conclusion
A fix for this issue was provided in version 9.0.0.1 of Rational Integration Tester.
Temporary fix
Comments
APAR Information
APAR number
PI43635
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
860
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-06-23
Closed date
2016-05-26
Last modified date
2016-05-26
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSN
UP
R870 PSN
UP
R871 PSN
UP
R900 PSY
UP
[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.6","Line of Business":{"code":"LOB45","label":"Automation"}}]
Document Information
Modified date:
14 October 2021