IBM Support

PI43277: Dynamic switching from polled to mbean (and vice versa) config m onitoring doesn't work.

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When dynamically switching from "polled" to "mbean" config
    monitoring (and vice versa), the server must be restarted in
    order for this update to take effect. This is set in the
    server.xml configuration element "config" within attribute
    "updateTrigger".
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server Liberty Profile                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Dynamic switching from polled to mbean  *
    *                      (and vice versa) config monitoring      *
    *                      doesn't work.                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    When dynamically switching from "polled" to "mbean" config
    monitoring (and vice versa), the server must be restarted in
    order for this update to take effect. This is set in the
    server.xml configuration element "config" within attribute
    "updateTrigger".
    

Problem conclusion

Temporary fix

  • The correct value will be used after the server is restarted.
    

Comments

APAR Information

  • APAR number

    PI43277

  • Reported component name

    LIBERTY PROFILE

  • Reported component ID

    5724J0814

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-06-18

  • Closed date

    2015-06-19

  • Last modified date

    2015-06-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LIBERTY PROFILE

  • Fixed component ID

    5724J0814

Applicable component levels

  • R850 PSY

       UP