IBM Support

PI39781: WORK IN PROGRESS CODE RELATED TO OSLC TRACE COLUMN IS INCLUDED IN GA BUILD

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Menu option "OSLC Trace.." exists in formal module window. This
    feature was not intended to be in GA Build since it is still
    work in progress.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of DOORS client.                                       *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Non-GA functionality, designed to report against OSLC        *
    * traceability, was mistakenly included in the release.        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This is resolved in the 9.6.1.3 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI39781

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    961

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-04-24

  • Closed date

    2015-06-26

  • Last modified date

    2015-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 961

Reference #: PI39781

Modified date: 26 June 2015