PI39233: RDZ V9.X PL/I AND LPEX EDITOR SHOWS MULTIPLE ERRONEOUS PROBLEM MARKERS WHEN THERE IS A SPACE WITHIN PIC SPECIFICATIONS

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Rational Developer for System z v9.x PL/I and LPEX Editor shows
    multiple erroneous problem markers when there is a space within
    PIC specifications
    
    E.g. DCL XX PIC '( n)n' cause the erroneous error markers. Note
    the  blank / space after the open bracket.
    
    The problem can also cause a loop, hang or long duration time
    before the problem markers appear. The number of problem markers
    can be large.
    

Local fix

  • Many problem markers disappear when the spaces are removed from
    "quote, open bracket, space(s)"
    e.g. change
    DCL XX PIC '( 9)9'
    to
    DCL XX PIC '(9)9'
    

Problem summary

  • The RDz PL/I Parser incorrectly identifies PIC specifications
    that contain space characters.
    

Problem conclusion

  • Modified the RDz PL/I Parser to accept PIC specifications that
    contain white space.
    
    The problem listed in this APAR has been resolved with
    IBM Rational Developer for System z V9.1.1.2 Fix Pack which
    is available from the Recommended Fixes support download page:
    http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI39233

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    900

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2015-04-16

  • Closed date

    2015-10-16

  • Last modified date

    2015-10-16

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R911 PSY

       UP

[{"Business Unit":{"code":"BU058","label":"IBM Infrastructure w\/TPS"},"Product":{"code":"SSTRMM","label":"IBM Developer for z\/OS"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"900","Line of Business":{"code":"LOB35","label":"Mainframe SW"}}]

Document Information

Modified date: