Fixes are available
Rational Developer for System z Fix Pack 1 (9.1.1.2) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.3) for 9.1.1.
Rational Developer for System z Interim Fix 1 for 9.1.1.3
Rational Developer for System z Fix Pack 1 (9.1.1.4) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.5) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.6) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.7) for 9.1.1.
Rational Developer for System z Fix Pack 1 (9.1.1.8) for 9.1.1
Rational Developer for System z Fix Pack 9 (9.1.1.9) for 9.1.1
APAR status
Closed as program error.
Error description
Rational Developer for System z - RDz - 9.0, 9.1 When opening Endevor COBOL element using CARMA "enhanced edit", wrong copybook version resolved. This problem occurs when Endevor preference is set to use an RDz property group to resolve some/all copybooks. The copybooks expected to be resolved from the property group SYSLIB, are not resolved when library/dataset in SYSLIB is using the <HLQ> RDz "variable".
Local fix
Change library(s) in SYSLIB to explicitly state the entire dataset name (i.e. don't use <HLQ>).
Problem summary
During Enhanced Edit, with property group (order: Property group/Endevor), copybooks may not be found although the dataset that contains the expected dependencies is specified in the SYSLIB. This happens when <HLQ> instead of the userid is specified as the High Level Qualifier in the Property Group's SYSLIB.
Problem conclusion
The RDz Endevor Enhanced Edit needed to substitute the <HLQ> for the user id when resolving the datasets in the Property Group's SYSLIB. The problem listed in this APAR has been resolved with IBM Rational Developer for System z V9.1.1.2 Fix Pack which is available from the Recommended Fixes support download page: http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
Temporary fix
Comments
APAR Information
APAR number
PI37429
Reported component name
RATL DEV FOR SY
Reported component ID
5724T0700
Reported release
910
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt / Xsystem
Submitted date
2015-03-19
Closed date
2015-10-16
Last modified date
2015-10-16
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL DEV FOR SY
Fixed component ID
5724T0700
Applicable component levels
R911 PSY
UP
Document Information
Modified date: