IBM Support

PI36387: DXL ERROR WHEN USER VIEWS MODULE PROPERTIES, WITH MODULE WINDOW OPEN AND PREVIOUS HISTORY HAS BEEN LOADED

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • To Reproduce:
    1. Create a new module, then create a new object, then create a
    new baseline.
    2. Right-click on the module window and open the module
    properties, click the History tab and click Load Previous, then
    Click Ok.
    3. Now, leave that module open and go back to the database
    explorer window, then-right click on the module and click
    properties.
    
    Receive DXL error:
    -R-E- DXL: <standard/history/historyTab.inc:1256> operation
    requires a current module
    Backtrace:
     <standard/history/historyTab.inc:1474>
     <standard/history/historyTab.inc:1600>
     <standard/itemProperties/properties.dxl:662>
     <standard/itemProperties/properties.dxl:853>
     <config/baseWindowCallbacks.inc:1386>
     <config/baseWindowCallbacks.inc:1393>
    
    
    Workaround :
    Close the module window and then right clicking on the
    module in the database explorer window and clicking properties
    will not
    cause the DXL error to appear.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * all                                                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * fixed in DOORS 9.6.1.3                                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This is resolved in the 9.6.1.3 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI36387

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    951

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-03-05

  • Closed date

    2015-06-26

  • Last modified date

    2015-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.5.1

Reference #: PI36387

Modified date: 26 June 2015