  • If you create an OSLC link from RQM or RTC to a DOORS object
    that contains two spaces in its object heading/object text, an
    extra history entry gets added showing the object heading/object
    text was modified. It appears that the rich text of the object
    heading/object text is actually modified.
    
    Reproduced with RQM/RTC 5.0.1 and DOORS/DWA 9.6.0.1.
    
    Steps to reproduce:
    1. Configure DOORS/RTC OSLC environment
    2. In a DOORS module create an object with object heading or
    object text separated by two spaces, e.g ONE  TWO
    3. In RTC, open an existing Work Item and go to the "Links" tab
    4. Add Related Implements Requirement link to object in module
    created during step 2
    5. Save this RTC Work Item
    6. Go look at the object history for this object
    
    You will see there is a history entry showing the object created
    and the object heading/text set for step 2. But you will also
    see another history entry where it will say the object
    heading/text was modified from ONE  TWO to ONE  TWO. Doesn't
    appear to be much of a change, but if you look at the rich text
    before/after it is different. This extra history entry is not
    expected.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Extra history entries are being created for modified         *
    * attributes when creating OSLC links from CLM.ORS.            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This is resolved in the 9.6.1.3 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI36095

  • Reported component name

    RATL DOORS NG

  • Reported component ID

    5724W87NG

  • Reported release

    960

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-03-02

  • Closed date

    2015-06-26

  • Last modified date

    2015-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.6

Reference #: PI36095

Modified date: 26 June 2015