IBM Support

PI34040: CICS AGENT ON RD&T SYSTEMS FAILS TO START WITH S0C4 ABEND

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Attempts to start the CICS Agent on IBM Rational Development and
    Test Environment for System z (RD&T) systems fails with the
    following:
    
    JESMSGLG:
                           J E S 2  J O B  L O G  --  S Y S T E M  S
    0 W 1  --  N O D E  S 0 W 1
    
    17.16.57 JOB00220 ---- FRIDAY,    10 OCT 2014 ----
    17.16.57 JOB00220  IRR010I  USERID IBMUSER  IS ASSIGNED TO THIS
    JOB.
    17.16.57 JOB00220  ICH70001I IBMUSER  LAST ACCESS AT 17:16:41 ON
    FRIDAY, OCTOBER 10, 2014
    17.16.57 JOB00220  $HASP373 RITAGT51 STARTED - INIT 1    - CLASS
    A - SYS S0W1
    17.16.57 JOB00220  IEF403I RITAGT51 - STARTED - TIME=17.16.57
    17.16.58 JOB00220  IEA995I SYMPTOM DUMP OUTPUT  141
       141             SYSTEM COMPLETION CODE=0C4  REASON
    CODE=00000011
       141              TIME=17.16.58  SEQ=00607  CPU=0000
    ASID=001A
       141              PSW AT TIME OF ERROR  078D0000   8506FA24
    ILC 4  INTC 11
       141                NO ACTIVE MODULE FOUND
       141                NAME=UNKNOWN
       141                DATA AT PSW  0506FA1E - D00C58A1  000058CA
    0010C0B0
       141                GR 0: 00000010   1: 1F953710
       141                   2: 1EECEF50   3: 00000000
       141                   4: 00000000   5: 00000000
       141                   6: 00000000   7: 00000000
       141                   8: 00000000   9: 00000000
       141                   A: 1EECEF50   B: 00000000
       141                   C: 00000000   D: 1F953F18
       141                   E: 00FD6DA8   F: 8506F9F8
       141              END OF SYMPTOM DUMP
    17.16.58 JOB00220  IEF450I RITAGT51 RITCICS - ABEND=S0C4 U0000
    REASON=00000011  142
       142                     TIME=17.16.58
    17.16.58 JOB00220  IEF404I RITAGT51 - ENDED - TIME=17.16.58
    17.16.58 JOB00220  $HASP395 RITAGT51 ENDED
    ------ JES2 JOB STATISTICS ------
      10 OCT 2014 JOB EXECUTION DATE
               75 CARDS READ
            1,095 SYSOUT PRINT RECORDS
                0 SYSOUT PUNCH RECORDS
               83 SYSOUT SPOOL KBYTES
             0.01 MINUTES EXECUTION TIME
    
    SYSOUT:
    
    CEE3204S The system detected a protection exception (System
    Completion Code=0C4).
             From compile unit
    //'ANTZ.RIT.V8602.HHL.RITCPP(RITCICS)' at entry point main at
    compile unit offset +00573D7E
              at entry offset +00573D7E at address 1EE77F1E.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester working with the    *
    * CICS DPL Agent.                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The CICS DPL Agent could cause an S0C4 ABEND when used in    *
    * the IBM Rational Development and Test Environment for System *
    * z.                                                           *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 8.7.0 of Rational
    Integration Tester.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI34040

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    860

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-02-03

  • Closed date

    2015-05-20

  • Last modified date

    2015-05-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSY

       UP



Document information

More support for: Rational Test Workbench

Software version: 8.6

Reference #: PI34040

Modified date: 20 May 2015