IBM Support

PI33631: DWA CANNOT LOAD MODULES CONFIGURED FOR DOORS ANALYST

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • DWA will timeout when attempting to open modules configured for
    DOORS Analyst.
    The Analyst integration creates an object level attribute
    "uml.file.u2" which stores binary information as text.
    These attribute values can be several Meg in size for each
    object in the module. DWA is unable to process this huge volume
    of data and user will see a timeout out.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users and environments affected                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * DWA cannot load modules configured for DOORS Analyst         *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • Added new command line flag for interop "-dwaIgnoreAnalystUml".
    This will stop the content for attribute "UML File.u2" being
    converted to XHTML. The empty string will be passed up for this
    attribute.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI33631

  • Reported component name

    TLOGIC DOORS WE

  • Reported component ID

    5724V97WA

  • Reported release

    960

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-28

  • Closed date

    2015-03-12

  • Last modified date

    2015-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS WE

  • Fixed component ID

    5724V97WA

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.6

Reference #: PI33631

Modified date: 12 March 2015