PI33534: RATIONAL DEVELOPER FOR SYSTEM Z (RDZ) JOBS WITH RDZ NOTIFY THAT ARE PURGED ARE NOT REMOVED FROM NOTIFY QUEUE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Rational Developer for System z - RDz - v9.1.1
    
    When you submit a job, select Notify on the popup dialog, and
    then purge the job the Notify is not removed.  Therefore, the
    NOTIFY is still displayed in the client progress bar.
    

Local fix

  • If you don't specify Notify or you don't use Purge then you
    will not see this issue.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED: 01.RDz user who use JES notify.              *
    ****************************************************************
    * PROBLEM DESCRIPTION: 01.RDz JES notify fails for purged      *
    *                         jobs.                                *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    01.Rational Developer for System z JES notify fails for purged
       jobs. JES notify does not notice the job ended and keeps
       reporting the job as active.
    

Problem conclusion

  • 01.JMON has been corrected to detect purged jobs.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI33534

  • Reported component name

    RD/Z HOST

  • Reported component ID

    5724T0723

  • Reported release

    910

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-27

  • Closed date

    2015-03-18

  • Last modified date

    2015-04-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Modules/Macros

  • FEJJMON
    

Fix information

  • Fixed component name

    RD/Z HOST

  • Fixed component ID

    5724T0723

Applicable component levels

  • R910 PSY UI26082

       UP15/04/01 I 1000

Fix is available

  • Select the PTF appropriate for your component level. You will be required to sign in. Distribution on physical media is not available in all countries.



Document information

More support for: Rational Developer for System z

Software version: 9.1

Reference #: PI33534

Modified date: 01 April 2015