  • Closed as program error.

Error description

  • Where an MQ Stubs running on a single RIT Agent Engine runs out
    of MQ connections it stops picking up messages from the queue.
    

Local fix

  • This problem can be mitigated by only running one MQ Stub per
    RIT Agent Engine.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester working with        *
    * WebSphere MQ.                                                *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In minimizing the number of WebSphere MQ connections that it *
    * consumed, Rational Integration Tester caused significant     *
    * performance degradation when many MQ-based stubs were run in *
    * the same "engine" simultaneously.                            *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 8.7.0.1 of Rational
    Integration Tester. The "Allow connections to be managed
    automatically" option was added to the Advanced tab of the
    transport. This option tells Rational Integration Tester to use
    more MQ connections than it normally would in order to achieve
    better performance as more MQ stubs are run. If the option is
    cleared, Rational Integration Tester reverts to its previous
    behavior.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI33356

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    860

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-23

  • Closed date

    2015-05-20

  • Last modified date

    2015-05-20

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSY

       UP



Document information

More support for: Rational Test Workbench

Software version: 8.6

Reference #: PI33356

Modified date: 20 May 2015