IBM Support

PI32147: WHEN A MODULE/VIEW IS LINKED TO A RQM TEST PLAN, LOADING COVERAGE VIEW IN RQM UI IS EXTREMELY SLOW

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • This issue is specific to shape/size of the module/view that is
    linked to RQM Test Plan.
    
    Steps to reproduce:
    Create a module with 1000 objects
    Create 300 text attributes and assign some value
    Login to RQM
    Go to Requirement Collection Links section
    Create a link to the module created in first step
    Select "Coverage" from the drop-down for "View as"
    
    Loading the details takes a long time depending on the number of
    requirements in the requirement collection and the shape of
    requirement.
    This is because RQM uses oslc.properties, querying only for
    title and modified properties of each requirement in the
    collection. This takes long to return a response depending on
    shape of requirement.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users and environments affected                          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * When a module/view is linked to a RQM test plan, loading     *
    * coverage view in RQM is extremely slow                       *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Client side fix.
    

Problem conclusion

  • Performance improvements and code optimization have been made to
    DWA
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI32147

  • Reported component name

    TLOGIC DOORS WE

  • Reported component ID

    5724V97WA

  • Reported release

    952

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2015-01-05

  • Closed date

    2015-03-12

  • Last modified date

    2015-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS WE

  • Fixed component ID

    5724V97WA

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.5.2

Reference #: PI32147