IBM Support

PI31000: RATIONAL DEVELOPER FOR SYSTEM Z (RDZ): RDZ CLIENT 8.5.1.5, CRRZI 009E WORKING OFFLINE IN A Z/OS PROJECT AND OPENING COPYBOOK

Subscribe to this APAR

By subscribing, you receive periodic emails alerting you to the status of the APAR, along with a link to the fix after it becomes available. You can track this item individually or track all items by product.

Notify me when this APAR changes.

Notify me when an APAR for this component changes.

APAR status

  • Closed as program error.

Error description

  • Rational Developer for System z (RDz): RDz 8.5.1.5 receives
    error
    CRRZI0019E working offline in a z/OS Project and opening a copy
    member when the SYSLIB is defined with <USERID> in the Property
    Group.
    CRRZI0019E : The copy file cannot be found in the SYSLIB
    library.
    Verify that both the file and the library are allocated properly
    is displayed on.
    

Local fix

  • Define SYSLIB with <HLQ> instead of <USERID> in the Property
    Group.
    

Problem summary

  • The problem is that <USERID> has no meaning when a project is
    offline, since that depends on what userid the user connects
    with and, in the offline case, a connection is not relevant.
    

Problem conclusion

  • The fix is that when a project is taken offline we now save the
    userid associated with the system associated with each
    subproject.  This value can then be referenced when the project
    is offline.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI31000

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt / Xsystem

  • Submitted date

    2014-12-05

  • Closed date

    2016-03-28

  • Last modified date

    2016-03-28

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R851 PSY

       UP



Document information

More support for: Rational Developer for System z

Software version: 851

Reference #: PI31000