IBM Support

PI29520: DOORS CHANGE INTEGRATION HITS LIMIT IF TOO MANY ATTRIBUTES ARE USED IN DOORS_OSLC PROCESS FILE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Using Rational Doors and Change integration a limit can be hit
    where the link from DOORS to change will no longer produce
    output because the query has exceeded the Informix database
    limit.
    
    Workaround is to use less attributes.    The approximate number
    of attributes where the problem starts to occur is 2500 but that
    is not exact.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users.                                                   *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * DOORS change integration hits a limit if too many attributes *
    * are used in DOORS OSLC process file                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Supplemental guidance added to KC.
    

Problem conclusion

  • This has been resolved in the 9614 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI29520

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    960

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-11-12

  • Closed date

    2015-10-23

  • Last modified date

    2015-10-23

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.6

Reference #: PI29520

Modified date: 23 October 2015