PI27897: RIT SPENDS A LOT OF TIME TRYING TO RESOLVE A DATABASE IP TO A HOSTNAME

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • You have done a recording of a database. Clicking the
    database recorded events is taking a huge amount of time to
    display the details. The tool appears to hang for a long time
    and you
    are unable to create a test from those events.
    This happened when the database transport is set to an IP
    that is not mapped to a hostname. Rational Integration Tester
    then spent a lot of
    time trying to resolve the IP to a hostname.
    A workaround consists of resolving the IP address to a hostname
    in Rational Integration Tester's
    hosts file.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester who record JDBC     *
    * events.                                                      *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * f a user recorded JDBC events and then clicked on those      *
    * recorded events in the Recording Studio perspective,         *
    * Rational Integration Tester could appear to hang.  This was  *
    * caused by Rational Integration Tester attempting to resolve  *
    * or contact the host that the events were originally recorded *
    * from.  If the host was not accessible, extremely long delays *
    * would occur, leading the user to believe that the            *
    * application had hung.                                        *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • A fix for this issue was provided in version 8.7.0.1 of Rational
    Integration Tester. Users should no longer experience these
    delays.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI27897

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    860

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-10-17

  • Closed date

    2015-05-19

  • Last modified date

    2015-05-19

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSN

       UP

  • R870 PSY

       UP



Document information

More support for: Rational Test Workbench

Software version: 8.6

Reference #: PI27897

Modified date: 19 May 2015