  • Closed as program error.

Error description

  • If a resource reference has a type and a binding to a custom
    service object that implements the type but does not regist
    er the type in the service registry, then the lookup will fa
    il.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:  All users of IBM WebSphere Application      *
    *                  Server Liberty Profile                      *
    ****************************************************************
    * PROBLEM DESCRIPTION: Resource references must match based on *
    *                      type rather than name only              *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    Indirect lookups for resource references should locate the
    target resource based on the name only, but the algorithm was
    also matching based on type.  If the resource reference type was
    incorrect or the target resource was not registered in the
    service registry with all the types it supports, then the
    indirect lookup fails.
    

Problem conclusion

Temporary fix

Comments

APAR Information

  • APAR number

    PI25789

  • Reported component name

    LIBERTY PROFILE

  • Reported component ID

    5724J0814

  • Reported release

    850

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-09-17

  • Closed date

    2014-09-20

  • Last modified date

    2014-11-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    LIBERTY PROFILE

  • Fixed component ID

    5724J0814

Applicable component levels

  • R850 PSY

       UP

[{"Business Unit":{"code":"BU059","label":"IBM Software w\/o TPS"},"Product":{"code":"SSEQTP","label":"WebSphere Application Server"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"850","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
27 April 2022