IBM Support

PI22381: RRDG DOESN'T PREFILL & DISPLAY THE DEFAULT VALUES DEFINED IN DTA FILE IN THE POPUP WINDOW WHEN EXPORTING

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Steps to reproduce
    1. Create a RPE dta file which has variable with default value
    2. In DOORS, open a module, open RRDG
    
    File > Export > Document Generation > Export
    
    3. In Document Generation - DOORS window
    
    Choose an above dta template file
    
    Click on Export
    
    4. In Template Parameters - DOORS window
    
    There are all RPE variables, but without default values
    displayed
    
    Expected Results
    RRDG should pre-fill the default values from dta file
    
    Actual Results
    RRDG doesn't pre-fill the default values of variable from dta
    
    Additional Information
    RRDG load the values from dta file, but it just doesn't display
    & prefill in window for end users review.
    i.e. if proceed as it is without modification, in the output
    doc, it use/print the default value in dta.
    These current behaviour confuses end users.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of the DOORS Document Generation functionality         *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Steps to reproduce                                           *
    * 1. Create a RPE dta file which has variable with default     *
    * value                                                        *
    * 2. In DOORS, open a module, open RRDG                        *
    *                                                              *
    * File > Export > Document Generation > Export                 *
    *                                                              *
    * 3. In Document Generation - DOORS window                     *
    *                                                              *
    * Choose an above dta template file                            *
    *                                                              *
    * Click on Export                                              *
    *                                                              *
    * 4. In Template Parameters - DOORS window                     *
    *                                                              *
    * There are all RPE variables, but without default values      *
    * displayed                                                    *
    *                                                              *
    * Expected Results                                             *
    * RRDG should pre-fill the default values from dta file        *
    *                                                              *
    * Actual Results                                               *
    * RRDG doesn't pre-fill the default values of variable from    *
    * dta                                                          *
    *                                                              *
    * Additional Information                                       *
    * RRDG load the values from dta file, but it just doesn't      *
    * display                                                      *
    * & prefill in window for end users review.                    *
    * i.e. if proceed as it is without modification, in the output *
    * doc, it use/print the default value in dta.                  *
    * These current behaviour confuses end users.                  *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This is a client side fix
    

Problem conclusion

  • The code has been changed so that the information is now
    pre-filled
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI22381

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    960

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-07-21

  • Closed date

    2014-12-05

  • Last modified date

    2014-12-05

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R960 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.6

Reference #: PI22381

Modified date: 05 December 2014