IBM Support

PI21394: RATIONAL DEVELOPER FOR SYSTEM Z (RDZ) PLI OUTLINE VIEW EMPTY WHEN USING %DO %END STATEMENTS

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Rational Developer for System z - RDz - v8.5.1.4
    PLI program that has %DO %END statements fails to display the
    outline view.
    
    Below is an example of a program that has the %DO and %END
    statements:
    Test1 : PROC;
    %DCL PUT_TEST CHAR;
    %PUT_TEST = 'YES';
    
    %IF PUT_TEST = 'YES'%THEN
    %DO;
      dcl test char(2);
      test = 'NO';
    %END;
    
    dcl
    1 Data1,
       5 a char(20),
       5 b bit(1);
    
    End Test1;
    
    The Data structures do not appear in the Outline view unless
    the %DO and %END are removed.
    

Local fix

  • none available
    

Problem summary

  • The RDz PL/I outline view code improperly handled %DO - %END
    preprocessor blocks.
    

Problem conclusion

  • Modified outline view code to properly handle %DO - %END
    preprocessor blocks.
    
    The problem listed in this APAR has been resolved with
    IBM Rational Developer for System z V8.5.1.6 Fix Pack which
    is available from the Recommended Fixes support download page:
    http://www-1.ibm.com/support/docview.wss?rs=2294&uid=swg27006335
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI21394

  • Reported component name

    RATL DEV FOR SY

  • Reported component ID

    5724T0700

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-07-04

  • Closed date

    2015-02-04

  • Last modified date

    2015-02-04

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL DEV FOR SY

  • Fixed component ID

    5724T0700

Applicable component levels

  • R851 PSY

       UP



Document information

More support for: Rational Developer for System z

Software version: 851

Reference #: PI21394

Modified date: 04 February 2015