IBM Support

PI20773: RECORDING THE SOFTWARE AG WEBMETHODS SERVICE PUB.PUBLISH:PUBLISH CAUSES SERVER PERFORMANCE ISSUES

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • If you use Recording Studio to record the pub.publish:publish
    service it can cause the webMethods server to slow down and
    require a re-start.
    
    The following error is seen multiple times in the webMethods
    server log:
    
    2014-05-22 11:39:00 CDT [ISP.0090.0004E]
    com.greenhat.wm.pipeline.GHTRecordingFilter.process -- Exception
    occurred when publishing the input event record for service
    pub.publish:publish : com.wm.app.b2b.server.ServiceException:
    java.lang.reflect.InvocationTargetException: StackOverflowError
    
    WORKAROUND:
    
    Do not record the pub.publish:publish service.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration Tester who are using the   *
    * Software AG webMethods Integration Server transport          *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * A user may see a stack overflow error when recording events  *
    * on the Software AG webMethods Integration Server transport.  *
    * This was caused by recording the pub.publish:publish service *
    * which should not be allowed.                                 *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The problem has been resolved in Rational Integration Tester
    version 8.6.0.1.  Users are no longer able to record the
    pub.publish:publish service which avoids the stack overflow.
    Users should have no need to record this service.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI20773

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-25

  • Closed date

    2014-09-01

  • Last modified date

    2014-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSY

       UP