IBM Support

PI20736: DOORS LINKSET PAIRINGS ARE NOT COPIED WHEN A MODULE CONTAINING IS COPY-PASTED.

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • This behavior is seen in DOORS 9.5.2.X and also in latest DOORS
    9.6
    
    Steps to replicate:
    ==============
    1> Open any DOORS Formal Module in Exclusive Edit Mode -- File
    -- Module Properties -- Links.
    2> Create a Linkset Pairing, save and close the Module.
    3> Copy the aforementioned Module and paste it either in the
    same Project/Folder as the original one or in any other location
    in the Database.
    4> Access the Module Properties and we'd observe that the
    Linkset Pairing is not retained in the Copied over Module.
    
    This impacts more when in the original Module you have set
    restrictions of allowing outgoing links to target Modules in the
    list and the same isn't retained in the copied over Module.
    
    This issue was not seen in DOORS 9.3.0.7
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users                                                    *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * Linkset pairings were not being copied.                      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This is resolved in the 9.6.1.3 release.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI20736

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    952

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-25

  • Closed date

    2015-06-26

  • Last modified date

    2015-06-26

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.5.2

Reference #: PI20736