IBM Support

PI20576: SWIFT MESSAGE MT102 ORDERING CUSTOMER FIELD DOES NOT OFFER 50F TYPE

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • When using the MT102 SWIFT schema in the Message Editor it is
    not possible to select type 50F for the Ordering Customer field.
    Types 50A & 50K are available only.
    
    WORKAROUND:
    
    1. Delete the existing Ordering Customer field.
    2. Right-click on the Common Field Elements node and click Add
    Child > User Defined > String
    3. Name the field "50F"
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Integration tester who use SWIFT       *
    * messages                                                     *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * A user is not able to add the 50F option for the "Ordering   *
    * customer" fields in SWIFT MT 101 and MT 102 messages despite *
    * the SWIFT specification stating that it is a valid option.   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • In Rational Integration Tester 8.6.0.1 it is possible to add the
    50F option as per the specification.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI20576

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-23

  • Closed date

    2014-09-01

  • Last modified date

    2014-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSY

       UP



Document information

More support for: Rational Test Workbench

Software version: 8.5.1

Reference #: PI20576

Modified date: 01 September 2014