IBM Support

PI20564: UNNECESSARY MESSAGE APPEARS IN ANALYSIS WIZARD

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • The following scenario results in DOORS reporting unnecessary
    message "You have already chosen to analyze a specific formal
    module. So this option cannot be selected"
    
    Also tested in DOORS 9.6
    
    Open module
    Select Analysis>Wizard
    Step 1 Leave as default
    Step 2 Select All formal modules
    Step 3 Leave as default
    Step 4 Select Recursive analysis and "Display information only
    from selected modules"
    Click Finish
    
    Select Analysis>Wizard again
    Step 1 Leave as default
    Step 2 Select specific module this time
    Step 3 leave as default
    As soon as you click next and go to step 4 receive warning "You
    have already chosen to analyze a specific formal module. So this
    option cannot be selected" because DOORS has remembered the
    settings from the previous run of the analysis wizard.
    
    DOORS should not remember this setting if the user selects a
    specific module in the wizard. The message should only appear if
    the user tries to select this radio button.
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * all users/environments affected                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * The following scenario results in DOORS reporting            *
    * unnecessary message                                          *
    * "You have already chosen to analyze a specific formal        *
    * module. So this option cannot be selected"                   *
    *                                                              *
    * Open module                                                  *
    * Select Analysis>Wizard                                       *
    * Step 1 Leave as default                                      *
    * Step 2 Select All formal modules                             *
    * Step 3 Leave as default                                      *
    * Step 4 Select Recursive analysis and "Display information    *
    * only from selected modules"                                  *
    * Click Finish                                                 *
    *                                                              *
    * Select Analysis>Wizard again                                 *
    * Step 1 Leave as default                                      *
    * Step 2 Select specific module this time                      *
    * Step 3 leave as default                                      *
    * As soon as you click next and go to step 4 receive warning   *
    * "You have already chosen to analyze a specific formal        *
    * module. So this option cannot be selected"                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    This behavior does not affect data and can be ignored. This is a
    client side fix
    

Problem conclusion

  • This unnecessary message does not appear any more playing this
    scenario.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI20564

  • Reported component name

    TLOGIC DOORS

  • Reported component ID

    5724V61DR

  • Reported release

    950

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-06-23

  • Closed date

    2015-03-12

  • Last modified date

    2015-03-12

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS

  • Fixed component ID

    5724V61DR

Applicable component levels

  • R961 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.5

Reference #: PI20564

Modified date: 12 March 2015