Fixes are available
Rational Integration Tester Fix Pack 2 (8.6.0.2) for 8.6
Rational Performance Test Server Fix Pack 2 (8.6.0.2) for 8.6
Rational Test Virtualization Server Fix Pack 2 (8.6.0.2) for 8.6
Rational Integration Tester Fix Pack 3 (8.6.0.3) for 8.6
Rational Performance Test Server Fix Pack 3 (8.6.0.3) for 8.6
Rational Test Virtualization Server Fix Pack 3 (8.6.0.3) for 8.6
Rational Integration Tester Fix Pack 4 (8.6.0.4) for 8.6
Rational Performance Test Server Fix Pack 4 (8.6.0.4) for 8.6
Rational Test Virtualization Server Fix Pack 4 (8.6.0.4) for 8.6
APAR status
Closed as program error.
Error description
With pop-up editor windows configured, changes made to the Filter expressions of the Test Data Iterator action are not always saved. With the docked editor changes are saved when you click the Apply button. STEPS TO REPRODUCE: 1. Create a test with a Test Data Iterator and at least one tag 2. Configure the Iterator test data source and click the Filter tab. 3. Enter a value in the Required Value tab and click OK. 4. Re-open the test action and edit the Required Value value and click OK EXPECTED RESULTS: The subsequent changes are saved. ACTUAL RESULTS: Changes are not saved. WORKAROUND: Hit Enter or click elsewhere in the frame to close that cell after modifying it. Use the docked editor with the Apply button.
Local fix
Problem summary
**************************************************************** * USERS AFFECTED: * * All users of Rational Integration Tester * **************************************************************** * PROBLEM DESCRIPTION: * * If a users edits the Test Data Iterator action and changes * * the value of the "Required Value" field on the Filter page * * then the change will not actually be saved unless the user * * first presses Enter or clicks elsewhere in the frame first. * **************************************************************** * RECOMMENDATION: * ****************************************************************
Problem conclusion
The problem has been resolved in version 8.6.0.2 of Rational Integration Tester and the value now saves correctly.
Temporary fix
Comments
APAR Information
APAR number
PI18128
Reported component name
RATL INTEGRA TE
Reported component ID
5725G79IT
Reported release
851
Status
CLOSED PER
PE
NoPE
HIPER
NoHIPER
Special Attention
NoSpecatt
Submitted date
2014-05-16
Closed date
2015-01-02
Last modified date
2015-01-02
APAR is sysrouted FROM one or more of the following:
APAR is sysrouted TO one or more of the following:
Fix information
Fixed component name
RATL INTEGRA TE
Fixed component ID
5725G79IT
Applicable component levels
R800 PSN
UP
R801 PSN
UP
R850 PSN
UP
R851 PSN
UP
R860 PSY
UP
Document Information
Modified date:
17 October 2021