IBM Support

PI17519: IN SPECIFIC SCENARIOS DWA CLIENT SESSION HANGS WHILE SWITCHING FROM DATABASE VIEW TO PROJECT VIEW

Subscribe

You can track all active APARs for this component.

APAR status

  • Closed as program error.

Error description

  • Steps to reproduce:
    - Create a folder at root level
    - Create a project in the folder
    - Create some modules within the project
    - For User A, assign None access to folder at root level
    - Assign full access to the project in the folder, for User A
    - Login to DWA (Database view is the default) as User A. Project
    shows up fine.
    - Now change switch Database View to Project View
    - DWA session hangs
    

Local fix

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of DWA                                                 *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * In specific scenarios the DWA client session hangs while     *
    * switching from database view to project view                 *
    *                                                              *
    * Steps to reproduce:                                          *
    * - Create a folder at root level                              *
    * - Create a project in the folder                             *
    * - Create some modules within the project                     *
    * - For User A, assign None access to folder at root level     *
    * - Assign full access to the project in the folder, for User  *
    * A                                                            *
    * - Login to DWA (Database view is the default) as User A.     *
    * Project                                                      *
    * shows up fine.                                               *
    * - Now change switch Database View to Project View            *
    * - DWA session hangs                                          *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • The code has been changed so that a hang no longer occurs in
    this scenario
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI17519

  • Reported component name

    TLOGIC DOORS WE

  • Reported component ID

    5724V97WA

  • Reported release

    951

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-05-08

  • Closed date

    2014-09-11

  • Last modified date

    2014-09-11

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    TLOGIC DOORS WE

  • Fixed component ID

    5724V97WA

Applicable component levels

  • R960 PSY

       UP



Document information

More support for: Rational DOORS

Software version: 9.5.1

Reference #: PI17519

Modified date: 11 September 2014