PI16635: When values are removed from a SOAP header the changes are not saved

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • When editing a SOAP message, properties can be set in the header
    by entering them in the Message Header tab.  If existing
    properties are removed they are still set in subsequent
    executions of the test.
    

Local fix

  • Exit from Rational Integration Tester after deleting the
    properties and restart.
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * Users of Rational Integration Tester who want to delete      *
    * properties from an HTTP message.                             *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If you delete properties that are set in the Message Header  *
    * tab of an HTTP message, they are not correctly removed.      *
    ****************************************************************
    * RECOMMENDATION:                                              *
    * Upgrade to Rational Integration Tester 8.6.0 or above.       *
    ****************************************************************
    

Problem conclusion

  • The problem has been fixed in Rational Integration Tester
    version 8.6.0
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI16635

  • Reported component name

    RATL TEST WORKB

  • Reported component ID

    5725G7900

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-23

  • Closed date

    2014-06-24

  • Last modified date

    2014-06-24

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL TEST WORKB

  • Fixed component ID

    5725G7900

Applicable component levels