IBM Support

PI15445: RIT AGENT FAILS "UPON DEPLOYING STUB" IF INVALID DISPLAY VARIABLE SET ON LINUX (I.E. FOR X SERVER HOST)

Subscribe

You can track all active APARs for this component.

 

APAR status

  • Closed as program error.

Error description

  • Where invalid values are configured for the X server DISPLAY on
    Red Hat Linux it has been seen that the Agent will produce an
    error such as:
    
    INFO: VirtualAppinstance1 (0): UserLocation: /root/user/X11
    connection rejected because of wrong authentication.
    INFO: VirtualAppinstance1 (0): X connection to localhost:10.0
    broken (explicit kill or server shutdown).
    
    This should be considered an error since the Agent does not make
    use of the X server GUI.
    

Local fix

  • Remove the DISPLAY variable from the system.
    
    (Alternatively correct the DISPLAY variable so there is a valid
    X server connection, which will not be used.)
    

Problem summary

  • ****************************************************************
    * USERS AFFECTED:                                              *
    * All users of Rational Test Virtualization Server deployed on *
    * a Unix platform                                              *
    ****************************************************************
    * PROBLEM DESCRIPTION:                                         *
    * If a user attempts to start a stub on a Rational Integration *
    * Tester Agent deployed to a Unix machine that has an invalid  *
    * DISPLAY variable set then the stub will not start correctly. *
    * Test Control Panel will show a failure to deploy. If the     *
    * user examines the Agent log file they will see errors such   *
    * as:                                                          *
    *                                                              *
    * INFO: VirtualAppinstance1 (0): UserLocation: /root/user/X11  *
    * connection rejected because of wrong authentication.         *
    * INFO: VirtualAppinstance1 (0): X connection to               *
    * localhost:10.0                                               *
    * broken (explicit kill or server shutdown).                   *
    ****************************************************************
    * RECOMMENDATION:                                              *
    ****************************************************************
    

Problem conclusion

  • This problem has been resolved in version 8.6.0.1 of Rational
    Integration Tester by ensuring that the DISPLAY variable is
    removed from the environment in the script the Agent uses to
    launch the stub.
    

Temporary fix

Comments

APAR Information

  • APAR number

    PI15445

  • Reported component name

    RATL INTEGRA TE

  • Reported component ID

    5725G79IT

  • Reported release

    851

  • Status

    CLOSED PER

  • PE

    NoPE

  • HIPER

    NoHIPER

  • Special Attention

    NoSpecatt

  • Submitted date

    2014-04-08

  • Closed date

    2014-09-01

  • Last modified date

    2014-09-01

  • APAR is sysrouted FROM one or more of the following:

  • APAR is sysrouted TO one or more of the following:

Fix information

  • Fixed component name

    RATL INTEGRA TE

  • Fixed component ID

    5725G79IT

Applicable component levels

  • R800 PSN

       UP

  • R801 PSN

       UP

  • R850 PSN

       UP

  • R851 PSN

       UP

  • R860 PSY

       UP

[{"Business Unit":{"code":"BU053","label":"Cloud & Data Platform"},"Product":{"code":"SSBLQQ","label":"Rational Test Workbench"},"Platform":[{"code":"PF025","label":"Platform Independent"}],"Version":"8.5.1","Line of Business":{"code":"LOB45","label":"Automation"}}]

Document Information

Modified date:
17 October 2021